Shielded enclosures
NU Labs is equipped with two shielded enclosures to provide the electromagnetic interference testing required by current military specifications. The Panashield chamber uses 20-inch carbon-impregnated cone material for RF absorption.
| Enclosure | Type | Dimensions | Conforms to |
|---|---|---|---|
| Panashield | Semi-anechoic shielded enclosure | 23′ × 16′ × 12′ · maximum table area of 12.6′ × 9′ | MIL-STD-461 |
| Universal Shielding Corp. | Shielded enclosure | 12′ × 9′ × 9′ · door 35.5″ × 84″ | — |
Power & field capability
- All power to both chambers is filtered
- DC through 480 V AC, up to 100 A
- LISN up to 800 V DC and 500 V AC, up to 200 A
- Field levels over 10 V/m, 10 kHz to 18 GHz
Standards
Standards we test to
| Standard | Scope |
|---|---|
| MIL-STD-461F & G | Electromagnetic compatibility |
| MIL-STD-1399 Sec. 300B & 300 Part 1 | Interface standard for shipboard systems |
| DOD-STD-1399 Sec. 070, Part 1 and MIL-STD-1399 Section 407 | DC magnetic field environment |